This is default featured slide 1 title

This is default featured slide 1 title

You can completely customize the featured slides from the theme theme options page. You can also easily hide the slider from certain part of your site like: categories, tags, archives etc. More »

Commercial Reverse osmosis Plant - 2000 LPH to 2 lakhs liters per hour

Commercial Reverse osmosis Plant - 2000 LPH to 2 lakhs liters per hour

We are Manufacturer & Suppliers of All type of Reverse Osmosis Plant in chennai , India More »

This is default featured slide 3 title

This is default featured slide 3 title

You can completely customize the featured slides from the theme theme options page. You can also easily hide the slider from certain part of your site like: categories, tags, archives etc. More »

This is default featured slide 4 title

This is default featured slide 4 title

You can completely customize the featured slides from the theme theme options page. You can also easily hide the slider from certain part of your site like: categories, tags, archives etc. More »

This is default featured slide 5 title

This is default featured slide 5 title

You can completely customize the featured slides from the theme theme options page. You can also easily hide the slider from certain part of your site like: categories, tags, archives etc. More »

 

Category Archives: RO Plant 250 LPH Supplier/manufacturer in Chennai

Reverse osmosis plant – 250 LPH

Reverse osmosis plant – 250 LPH

RRR ENVIRO SYSTEMS one of the leading Reverse osmosis plant manufacturer, supplier, Dealer & Exporter in Chennai Tamilnadu India.

Exploding population, industrial effluents, and reckless deforestation have depleted natural sources of pure water. Dependence on erratic monsoons to replenish these sources has proved extremely inadequate & expensive. Good management of existing water resources and untapped sources, along with recovery and recycling of Industrial effluents & municipal waste water, seem absolutely essential for the future of mankind.

Water Compliant :

Salty Water, Smell Water , Hard water , white deposits, colored water etc,

1 Water Source – Well,bore,Lake ,canal , brackish water ,Sea
2 Power Requirement-  1.5 HP power load
3 Monthly maintenance – Max Rs.1000
4 Production Capacity – 2000 liters to 3000 liters
5 People- 1000 people
6 Houses – 5 houses (only drinking & kitchen purpose)
7 Area Required-  1.5 m X 2.0 m

Principle of Reverse Osmosis

Reverse Osmosis system uses semi-permeable spiral wound membrane to separate and remove dissolved solids, organics, pyrogens, submicron colloidal matter and bacteria from water. Feed water is delivered under high pressure through permeators, where water permeates through the minute pores of the membrane and is delivered as purified product water.

Removal of Impurities
Impurities in the water are concentrated in the reject stream and flushed to drain.

Output Range
The system is available in a wide range of models for treating water quality of varying Total Dissolved Solids (TDS) with different flow rates.
Purity Standards Maintained
Maximum purity is attained by reducing
a) 95% – 99%

our expertise lies in planning plants as per requirement in areas like:
 Municipal corporation
 IT park
 Guest house & villas
 Housing societies
 Commercial Complexes
 multiple complexes
 Residential Apartments
 Residential complexes
 Industrial organizations
 Educational institutions

    1. 250 lph 210

Reverse Osmosis Plant

Reverse Osmosis System allows removal of particles as small as ions from solution. These are membrane based desalination processes which implement semi permeable membrane and are based on principle of reverse osmosis. These Reverse Osmosis System can reject up to 90-98% of dissolved salts and almost all organics, heavy metals, & even micro organism.

Institutional Reverse osmosis plant

REVERSE OSMOSIS PLANT – 250 LPH ,500 LPH ,1000 LPH

Our organization is counted among the dominating manufacturer, supplier, exporter and service provider of Institutional RO Systems in Chennai Tamilnadu India. Developed from high grade filtration systems, membranes, purification systems and other material, all our products are assured of having superior quality & giving remarkable purification results. Our high quality Institutional RO Systems are not just responsible for removing impurities from water but also for removing odor and bad taste. Further, clients can buy our purification systems in various standard models and specifications as per their requirements.

 

Available Model & Water Generation capacity

 

Student & Staff quantity
Requirement Water Per Day
 RRRES RO plant model
500 people
1500 -2000 litres
250 Litres Per hour
1000 People
3000- 4000 litres
500 Litres Per hour
1500 people
6000 – 8000 litres  
1000 Litres Per hour

 

Key Features:

 

  • Excellent performance
  • No leakage
  • Easy to install & operate
  • Durable membrane

 

Principle of Reverse Osmosis 

Reverse Osmosis system uses semi-permeable spiral wound membrane to separate and remove dissolved solids, organics, pyrogens, submicron colloidal matter and bacteria from water. Feed water is delivered under high pressure through permeators, where water permeates through the minute pores of the membrane and is delivered as purified product water.

Removal of Impurities
Impurities in the water are concentrated in the reject stream and flushed to drain.

Output Range
The system is available in a wide range of models for treating water quality of varying Total Dissolved Solids (TDS) with different flow rates.

Purity Standards Maintained 
Maximum purity is attained by reducing

  1. 95% – 99% of the TDS

 

 

 

REVERSE OSMOSIS PLANT – 2000 LPH ,3000 LPH ,5000 LPH 

Our organization is counted among the dominating manufacturer, supplier, exporter and service provider of Institutional RO Systems in Chennai Tamilnadu India. Developed from high grade filtration systems, membranes, purification systems and other material, all our products are assured of having superior quality & giving remarkable purification results. Our high quality Institutional RO Systems are not just responsible for removing impurities from water but also for removing odor and bad taste. Further, clients can buy our purification systems in various standard models and specifications as per their requirements.

 

Available Model & Water Generation capacity

 

Student & Staff quantity
Requirement Water Per Day
 RRRES RO plant model
2000 people
12000 -15000 litres
2000 Litres Per hour
5000 People
20000- 25000 litres
3000 Litres Per hour
7000 people
30000 – 40000 litres  
5000 Litres Per hour

 

Key Features:

 

  • Excellent performance
  • No leakage
  • Easy to install & operate
  • Durable membrane

 

Principle of Reverse Osmosis 

Reverse Osmosis system uses semi-permeable spiral wound membrane to separate and remove dissolved solids, organics, pyrogens, submicron colloidal matter and bacteria from water. Feed water is delivered under high pressure through permeators, where water permeates through the minute pores of the membrane and is delivered as purified product water.

Removal of Impurities
Impurities in the water are concentrated in the reject stream and flushed to drain.

Output Range
The system is available in a wide range of models for treating water quality of varying Total Dissolved Solids (TDS) with different flow rates.

Purity Standards Maintained 
Maximum purity is attained by reducing

  1. 95% – 99% of the TDS